Energy Performance Certificate

Flat 6, 4, West Holme, B9 4NJ

EPC Report

Energy rating

Current: 22 F | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 33 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 71 Potential: 71
Field Value
LMK KEY 0145-2848-7576-9096-8121
ADDRESS1 Flat 6
ADDRESS2 4, West Holme
ADDRESS3
POSTCODE B9 4NJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2016-03-18
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001096
COUNTY
LODGEMENT DATE 2016-04-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 581
ENERGY CONSUMPTION POTENTIAL 214
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 1164
HEATING COST POTENTIAL 448
HOT WATER COST CURRENT 494
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.57
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 6, 4, West Holme
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Ladywood
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-04-15 13:10:48
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100071487913
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew