Energy Performance Certificate

12, Observer Way, Kelvedon, CO5 9NZ

EPC Report

Energy rating

Current: 55 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 46 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 65 Potential: 65
Field Value
LMK KEY 0144-2849-6294-9178-0315
ADDRESS1 12, Observer Way
ADDRESS2 Kelvedon
ADDRESS3
POSTCODE CO5 9NZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-01-31
LOCAL AUTHORITY E07000067
CONSTITUENCY E14001590
COUNTY
LODGEMENT DATE 2018-02-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 304
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1128
HEATING COST POTENTIAL 889
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 61
TOTAL FLOOR AREA 119
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Observer Way, Kelvedon
LOCAL AUTHORITY LABEL Braintree
CONSTITUENCY LABEL Witham
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-02-06 21:05:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100090312824
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew