Energy Performance Certificate

31b, Albert Road, PO5 2SE

EPC Report

Energy rating

Current: 21 F | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 32 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 63 Potential: 63
Field Value
LMK KEY 0140-2823-7716-9708-4425
ADDRESS1 31b, Albert Road
ADDRESS2
ADDRESS3
POSTCODE PO5 2SE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-09-07
LOCAL AUTHORITY E06000044
CONSTITUENCY E14001432
COUNTY
LODGEMENT DATE 2018-09-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 581
ENERGY CONSUMPTION POTENTIAL 262
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 1021
HEATING COST POTENTIAL 377
HOT WATER COST CURRENT 293
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 48
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31b, Albert Road
LOCAL AUTHORITY LABEL Portsmouth
CONSTITUENCY LABEL Portsmouth South
POSTTOWN SOUTHSEA
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-09-10 14:34:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 1775000827
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew