Energy Performance Certificate

24 HIGH STREET, SUTTON-ON-TRENT, NG23 6QA

EPC Report

Energy rating

Current: 40 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 34 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 70 Potential: 70
Field Value
LMK KEY 0140-2143-7060-2109-9395
ADDRESS1 24 HIGH STREET
ADDRESS2 SUTTON-ON-TRENT
ADDRESS3
POSTCODE NG23 6QA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-06-07
LOCAL AUTHORITY E07000175
CONSTITUENCY E14001375
COUNTY
LODGEMENT DATE 2021-07-02
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 266
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1478
HEATING COST POTENTIAL 624
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 158
TOTAL FLOOR AREA 161
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24 HIGH STREET, SUTTON-ON-TRENT
LOCAL AUTHORITY LABEL Newark and Sherwood
CONSTITUENCY LABEL Newark
POSTTOWN NEWARK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-07-02 16:54:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100031447107
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000004
Address display
Nation ew