Energy Performance Certificate

39, Auckland Avenue, HU6 7SE

EPC Report

Energy rating

Current: 50 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 41 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 63 Potential: 63
Field Value
LMK KEY 0138-2873-7436-9695-8595
ADDRESS1 39, Auckland Avenue
ADDRESS2
ADDRESS3
POSTCODE HU6 7SE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-07-17
LOCAL AUTHORITY E06000010
CONSTITUENCY E14001314
COUNTY
LODGEMENT DATE 2015-07-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 358
ENERGY CONSUMPTION POTENTIAL 205
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1333
HEATING COST POTENTIAL 986
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 112
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.94
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39, Auckland Avenue
LOCAL AUTHORITY LABEL Kingston upon Hull, City of
CONSTITUENCY LABEL Kingston upon Hull North and Cottingham
POSTTOWN HULL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-07-20 09:19:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 21008304
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew