Energy Performance Certificate

31, Alscot Way, SE1 5XU

EPC Report

Energy rating

Current: 60 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 50 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 69 Potential: 69
Field Value
LMK KEY 0134-2853-7257-9805-4545
ADDRESS1 31, Alscot Way
ADDRESS2
ADDRESS3
POSTCODE SE1 5XU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-05-07
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2015-05-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 249
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 752
HEATING COST POTENTIAL 630
HOT WATER COST CURRENT 162
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 105
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Flat rate charging, room thermostat only
MULTI GLAZE PROPORTION 30
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Alscot Way
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-05-08 00:45:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 200003368926
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew