Energy Performance Certificate

100 Post Office Road, Seisdon, WV5 7HA

EPC Report

Energy rating

Current: 58 D | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 63 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 64 Potential: 64
Field Value
LMK KEY 0132-7327-1100-0778-4206
ADDRESS1 100 Post Office Road
ADDRESS2 Seisdon
ADDRESS3
POSTCODE WV5 7HA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-03-08
LOCAL AUTHORITY E07000196
CONSTITUENCY E14001316
COUNTY
LODGEMENT DATE 2022-03-15
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 162
ENERGY CONSUMPTION POTENTIAL 154
CO2 EMISSIONS CURRENT 19
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 18
LIGHTING COST CURRENT 243
LIGHTING COST POTENTIAL 243
HEATING COST CURRENT 6505
HEATING COST POTENTIAL 6505
HOT WATER COST CURRENT 372
HOT WATER COST POTENTIAL 372
TOTAL FLOOR AREA 695
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric heat pump for water heating only
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric, Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 100 Post Office Road, Seisdon
LOCAL AUTHORITY LABEL South Staffordshire
CONSTITUENCY LABEL Kingswinford and South Staffordshire
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-03-15 22:23:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 71
LOW ENERGY FIXED LIGHT COUNT 71
UPRN 100031827960
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew