Energy Performance Certificate

79 KIRKWOOD, BURRADON, NE23 7PQ

EPC Report

Energy rating

Current: 33 F | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 17 | Potential: 39
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 39 Potential: 39
Field Value
LMK KEY 0129-0004-2202-5109-7204
ADDRESS1 79 KIRKWOOD
ADDRESS2 BURRADON
ADDRESS3
POSTCODE NE23 7PQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-02-02
LOCAL AUTHORITY E08000022
CONSTITUENCY E14001183
COUNTY
LODGEMENT DATE 2021-02-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 39
ENERGY CONSUMPTION CURRENT 810
ENERGY CONSUMPTION POTENTIAL 479
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 137
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 1789
HEATING COST POTENTIAL 963
HOT WATER COST CURRENT 372
HOT WATER COST POTENTIAL 231
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 79 KIRKWOOD, BURRADON
LOCAL AUTHORITY LABEL North Tyneside
CONSTITUENCY LABEL Cramlington and Killingworth
POSTTOWN BURRADON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-02-04 15:17:05
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 47052954
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000001
Address display
Nation ew