Energy Performance Certificate

The Steading, Low Park, West Woodburn, NE48 2SQ

EPC Report

Energy rating

Current: 61 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 53 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 80 Potential: 80
Field Value
LMK KEY 0121-2839-7150-9524-0545
ADDRESS1 The Steading
ADDRESS2 Low Park
ADDRESS3 West Woodburn
POSTCODE NE48 2SQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-05-21
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001285
COUNTY
LODGEMENT DATE 2014-05-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 219
ENERGY CONSUMPTION POTENTIAL 91
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1355
HEATING COST POTENTIAL 819
HOT WATER COST CURRENT 199
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 137
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 94
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 94% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Steading, Low Park, West Woodburn
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL Hexham
POSTTOWN HEXHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-05-21 14:32:43
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100110725420
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew