Energy Performance Certificate

Sylvanhurst, New Road, Rotherfield, TN6 3JS

EPC Report

Energy rating

Current: 67 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 61 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 80 Potential: 80
Field Value
LMK KEY 0120-2495-0086-2002-6121
ADDRESS1 Sylvanhurst
ADDRESS2 New Road
ADDRESS3 Rotherfield
POSTCODE TN6 3JS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2022-08-05
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001533
COUNTY
LODGEMENT DATE 2022-08-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 221
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 4.5
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 723
HEATING COST POTENTIAL 535
HOT WATER COST CURRENT 89
HOT WATER COST POTENTIAL 63
TOTAL FLOOR AREA 114
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Sylvanhurst, New Road, Rotherfield
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL Sussex Weald
POSTTOWN CROWBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2022-08-08 10:02:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100060109204
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew