Energy Performance Certificate

24 MANVERS ROAD, WALKLEY, SHEFFIELD, S6 2PJ

EPC Report

Energy rating

Current: 12 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 G Current: 12 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 25 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 79 Potential: 79
Field Value
LMK KEY 0120-2406-5090-2109-5561
ADDRESS1 24 MANVERS ROAD
ADDRESS2 WALKLEY
ADDRESS3 SHEFFIELD
POSTCODE S6 2PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 12
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-01-06
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001467
COUNTY
LODGEMENT DATE 2021-01-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 584
ENERGY CONSUMPTION POTENTIAL 128
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 2810
HEATING COST POTENTIAL 559
HOT WATER COST CURRENT 669
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 104
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 69
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 69% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24 MANVERS ROAD, WALKLEY, SHEFFIELD
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Central
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-01-07 18:01:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100051025409
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew