Energy Performance Certificate

11, Melbourne Place, BD5 0JA

EPC Report

Energy rating

Current: 52 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 40 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 61 Potential: 61
Field Value
LMK KEY 0116-2824-7492-9723-9335
ADDRESS1 11, Melbourne Place
ADDRESS2
ADDRESS3
POSTCODE BD5 0JA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-01-24
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001120
COUNTY
LODGEMENT DATE 2017-01-25
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 310
ENERGY CONSUMPTION POTENTIAL 188
CO2 EMISSIONS CURRENT 25
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 15
LIGHTING COST CURRENT 193
LIGHTING COST POTENTIAL 193
HEATING COST CURRENT 4614
HEATING COST POTENTIAL 2896
HOT WATER COST CURRENT 163
HOT WATER COST POTENTIAL 163
TOTAL FLOOR AREA 451
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 13
NUMBER HEATED ROOMS 13
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Melbourne Place
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford West
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-01-25 00:10:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 28
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100051194215
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew