Energy Performance Certificate

159 Main Road, Smalley, DE7 6DT

EPC Report

Energy rating

Current: 34 F | Potential: 105 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 105 A Potential: 105 A

Environmental impact (CO₂)

Current: 22 | Potential: 102
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 102 Potential: 102
Field Value
LMK KEY 0110-2338-4033-2392-9015
ADDRESS1 159 Main Road
ADDRESS2 Smalley
ADDRESS3
POSTCODE DE7 6DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 105
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-07-18
LOCAL AUTHORITY E07000032
CONSTITUENCY E14001066
COUNTY
LODGEMENT DATE 2022-07-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 102
ENERGY CONSUMPTION CURRENT 628
ENERGY CONSUMPTION POTENTIAL -27
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 167
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 1670
HEATING COST POTENTIAL 480
HOT WATER COST CURRENT 606
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 94
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 159 Main Road, Smalley
LOCAL AUTHORITY LABEL Amber Valley
CONSTITUENCY LABEL Amber Valley
POSTTOWN ILKESTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-07-18 11:30:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100030033143
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew