Energy Performance Certificate

14, Riverside, Wilton, SP2 0HW

EPC Report

Energy rating

Current: 67 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 66 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 86 Potential: 86
Field Value
LMK KEY 0109-2809-7138-9322-2501
ADDRESS1 14, Riverside
ADDRESS2 Wilton
ADDRESS3
POSTCODE SP2 0HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-07-21
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001460
COUNTY
LODGEMENT DATE 2012-07-21
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 191
ENERGY CONSUMPTION POTENTIAL 66
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 492
HEATING COST POTENTIAL 370
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Riverside, Wilton
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Salisbury
POSTTOWN SALISBURY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-07-21 17:36:11
TENURE
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100121054018
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew