Energy Performance Certificate

12, Hampton Grove, Meysey Hampton, GL7 5JN

EPC Report

Energy rating

Current: 57 D | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 47 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 63 Potential: 63
Field Value
LMK KEY 0105-2874-7149-9627-0215
ADDRESS1 12, Hampton Grove
ADDRESS2 Meysey Hampton
ADDRESS3
POSTCODE GL7 5JN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-04-24
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2013-01-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 128
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 1300
HEATING COST POTENTIAL 1101
HOT WATER COST CURRENT 163
HOT WATER COST POTENTIAL 103
TOTAL FLOOR AREA 159
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 8
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 8% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Hampton Grove, Meysey Hampton
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL South Cotswolds
POSTTOWN CIRENCESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-04-30 07:56:29
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 39
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10013396624
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew