Energy Performance Certificate

2, Creskeld View, Bramhope, LS16 9BG

EPC Report

Energy rating

Current: 67 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 65 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 83 Potential: 83
Field Value
LMK KEY 0102-2806-7289-9702-3501
ADDRESS1 2, Creskeld View
ADDRESS2 Bramhope
ADDRESS3
POSTCODE LS16 9BG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-08-06
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001322
COUNTY
LODGEMENT DATE 2012-08-06
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 189
ENERGY CONSUMPTION POTENTIAL 88
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 713
HEATING COST POTENTIAL 508
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 120
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.68
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Creskeld View, Bramhope
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds North West
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-08-06 16:36:13
TENURE
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 72345804
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display