Energy Performance Certificate

5, Bridge Fields, Kegworth, DE74 2FW

EPC Report

Energy rating

Current: 37 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 33 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 63 Potential: 63
Field Value
LMK KEY 0101-2848-7828-9997-0675
ADDRESS1 5, Bridge Fields
ADDRESS2 Kegworth
ADDRESS3
POSTCODE DE74 2FW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-02-18
LOCAL AUTHORITY E07000134
CONSTITUENCY E14001404
COUNTY
LODGEMENT DATE 2013-02-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 176
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 5.2
LIGHTING COST CURRENT 138
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 1620
HEATING COST POTENTIAL 983
HOT WATER COST CURRENT 332
HOT WATER COST POTENTIAL 176
TOTAL FLOOR AREA 151
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Bridge Fields, Kegworth
LOCAL AUTHORITY LABEL North West Leicestershire
CONSTITUENCY LABEL North West Leicestershire
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-02-19 19:56:00
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100030570625
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew