Energy Performance Certificate

3, School Terrace, Monkton, SA71 4LH

EPC Report

Energy rating

Current: 17 G | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 28 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 82 Potential: 82
Field Value
LMK KEY 0101-2848-7622-9807-2831
ADDRESS1 3, School Terrace
ADDRESS2 Monkton
ADDRESS3
POSTCODE SA71 4LH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-02-08
LOCAL AUTHORITY W06000009
CONSTITUENCY W07000100
COUNTY
LODGEMENT DATE 2013-02-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 633
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 112
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 871
HEATING COST POTENTIAL 205
HOT WATER COST CURRENT 635
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, School Terrace, Monkton
LOCAL AUTHORITY LABEL Pembrokeshire
CONSTITUENCY LABEL Mid and South Pembrokeshire
POSTTOWN PEMBROKE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-02-08 19:32:30
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 200003245170
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew