Energy Performance Certificate

2, Rushy Grove, RH16 4UW

EPC Report

Energy rating

Current: 81 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 82 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 83 Potential: 83
Field Value
LMK KEY 0100-3874-7147-9527-1815
ADDRESS1 2, Rushy Grove
ADDRESS2
ADDRESS3
POSTCODE RH16 4UW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 81
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-04-24
LOCAL AUTHORITY E07000228
CONSTITUENCY E14001366
COUNTY
LODGEMENT DATE 2013-04-24
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 95
ENERGY CONSUMPTION POTENTIAL 90
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 351
HEATING COST POTENTIAL 355
HOT WATER COST CURRENT 97
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 121
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.19 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.26 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2, Rushy Grove
LOCAL AUTHORITY LABEL Mid Sussex
CONSTITUENCY LABEL Mid Sussex
POSTTOWN HAYWARDS HEATH
CONSTRUCTION AGE BAND 2011
LODGEMENT DATETIME 2013-04-24 10:42:34
TENURE
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10090018524
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display