Energy Performance Certificate

4 CHESTNUT ROAD, SUTTON BENGER, SN15 4RP

EPC Report

Energy rating

Current: 25 F | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 33 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 69 Potential: 69
Field Value
LMK KEY 0100-2107-4110-2100-9225
ADDRESS1 4 CHESTNUT ROAD
ADDRESS2 SUTTON BENGER
ADDRESS3
POSTCODE SN15 4RP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2020-09-03
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2020-12-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 315
ENERGY CONSUMPTION POTENTIAL 108
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 1616
HEATING COST POTENTIAL 835
HOT WATER COST CURRENT 167
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 102
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 95
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 95% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 CHESTNUT ROAD, SUTTON BENGER
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South Cotswolds
POSTTOWN SUTTON BENGER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-12-01 21:24:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 21
UPRN 100121004193
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew