Energy Performance Certificate

15, Buttercup Close, SP2 8FA

EPC Report

Energy rating

Current: 79 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 79 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 80 Potential: 80
Field Value
LMK KEY 0099-3898-6467-9722-9081
ADDRESS1 15, Buttercup Close
ADDRESS2
ADDRESS3
POSTCODE SP2 8FA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-06-28
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001460
COUNTY
LODGEMENT DATE 2012-06-28
TRANSACTION TYPE new dwelling
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 105
ENERGY CONSUMPTION POTENTIAL 102
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 498
HEATING COST POTENTIAL 502
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 158
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 58.8
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.24 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.29 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 58.8% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 15, Buttercup Close
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Salisbury
POSTTOWN SALISBURY
CONSTRUCTION AGE BAND 2012
LODGEMENT DATETIME 2012-06-28 10:14:44
TENURE
FIXED LIGHTING OUTLETS COUNT 0
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10014608693
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew