Energy Performance Certificate

8a, Dee Banks, Great Boughton, CH3 5UX

EPC Report

Energy rating

Current: 64 D | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 59 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 66 Potential: 66
Field Value
LMK KEY 0098-2813-6557-9226-4441
ADDRESS1 8a, Dee Banks
ADDRESS2 Great Boughton
ADDRESS3
POSTCODE CH3 5UX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-05-27
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001163
COUNTY
LODGEMENT DATE 2016-05-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 191
ENERGY CONSUMPTION POTENTIAL 161
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 7.1
LIGHTING COST CURRENT 162
LIGHTING COST POTENTIAL 108
HEATING COST CURRENT 1748
HEATING COST POTENTIAL 1700
HOT WATER COST CURRENT 141
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 253
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 8a, Dee Banks, Great Boughton
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Chester North and Neston
POSTTOWN CHESTER
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2016-05-31 22:41:02
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 60
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 10012217657
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew