Energy Performance Certificate

18 PITTICK CLOSE, LONG HANBOROUGH, OX29 8FU

EPC Report

Energy rating

Current: 84 B | Potential: 96 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 96 A Potential: 96 A

Environmental impact (CO₂)

Current: 87 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 98 Potential: 98
Field Value
LMK KEY 0090-3518-0532-7006-3003
ADDRESS1 18 PITTICK CLOSE
ADDRESS2 LONG HANBOROUGH
ADDRESS3
POSTCODE OX29 8FU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 96
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-10-09
LOCAL AUTHORITY E07000181
CONSTITUENCY E14001090
COUNTY
LODGEMENT DATE 2020-10-09
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 84
ENERGY CONSUMPTION POTENTIAL -1
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.0
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 210
HEATING COST POTENTIAL 210
HOT WATER COST CURRENT 61
HOT WATER COST POTENTIAL 37
TOTAL FLOOR AREA 77
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, waste water heat recovery
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 18 PITTICK CLOSE, LONG HANBOROUGH
LOCAL AUTHORITY LABEL West Oxfordshire
CONSTITUENCY LABEL Bicester and Woodstock
POSTTOWN LONG HANBOROUGH
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2020-10-09 14:38:18
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10093355476
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew