Energy Performance Certificate

65 UNION CLOSE, EX39 3FE

EPC Report

Energy rating

Current: 79 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 82 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 83 Potential: 83
Field Value
LMK KEY 0081-0201-2109-4682-3910
ADDRESS1 65 UNION CLOSE
ADDRESS2
ADDRESS3
POSTCODE EX39 3FE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-08-06
LOCAL AUTHORITY E07000046
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2021-08-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 119
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 221
HEATING COST POTENTIAL 223
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.6
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 65 UNION CLOSE
LOCAL AUTHORITY LABEL Torridge
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN BIDEFORD
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2021-08-09 11:13:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10013842192
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew