Energy Performance Certificate

Flat 49, Cornwall House 55-57, High Street, SL1 1DZ

EPC Report

Energy rating

Current: 72 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 68 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 67 Potential: 67
Field Value
LMK KEY 0080-2789-2049-2607-8761
ADDRESS1 Flat 49
ADDRESS2 Cornwall House 55-57
ADDRESS3 High Street
POSTCODE SL1 1DZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-04-01
LOCAL AUTHORITY E06000039
CONSTITUENCY E14001477
COUNTY
LODGEMENT DATE 2023-04-07
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 187
ENERGY CONSUMPTION POTENTIAL 191
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 507
HEATING COST POTENTIAL 353
HOT WATER COST CURRENT 252
HOT WATER COST POTENTIAL 230
TOTAL FLOOR AREA 92
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostats only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Room thermostats only
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 9.31
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 49, Cornwall House 55-57, High Street
LOCAL AUTHORITY LABEL Slough
CONSTITUENCY LABEL Slough
POSTTOWN SLOUGH
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2023-04-07 09:24:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10090768827
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display
Nation ew