Energy Performance Certificate

26 PARK DALE, CASTLEFORD, WF10 2QP

EPC Report

Energy rating

Current: 86 B | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 76 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 81 Potential: 81
Field Value
LMK KEY 0080-2712-0010-9301-1665
ADDRESS1 26 PARK DALE
ADDRESS2 CASTLEFORD
ADDRESS3
POSTCODE WF10 2QP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2019-09-02
LOCAL AUTHORITY E08000036
CONSTITUENCY E14001428
COUNTY
LODGEMENT DATE 2020-10-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 127
ENERGY CONSUMPTION POTENTIAL 96
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 889
HEATING COST POTENTIAL 796
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 144
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 30
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26 PARK DALE, CASTLEFORD
LOCAL AUTHORITY LABEL Wakefield
CONSTITUENCY LABEL Pontefract, Castleford and Knottingley
POSTTOWN CASTLEFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2020-10-30 11:14:07
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 63180725
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display
Nation ew