Energy Performance Certificate

5 Chandlers Court, HU9 1FB

EPC Report

Energy rating

Current: 76 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 71 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 73 Potential: 73
Field Value
LMK KEY 0080-2639-0040-2002-7251
ADDRESS1 5 Chandlers Court
ADDRESS2
ADDRESS3
POSTCODE HU9 1FB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2022-04-01
LOCAL AUTHORITY E06000010
CONSTITUENCY E14001313
COUNTY
LODGEMENT DATE 2022-04-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 223
ENERGY CONSUMPTION POTENTIAL 210
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 224
HEATING COST POTENTIAL 174
HOT WATER COST CURRENT 284
HOT WATER COST POTENTIAL 178
TOTAL FLOOR AREA 56
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.14
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Chandlers Court
LOCAL AUTHORITY LABEL Kingston upon Hull, City of
CONSTITUENCY LABEL Kingston upon Hull East
POSTTOWN HULL
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2022-04-01 09:52:15
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10000203806
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000003
Address display
Nation ew