Energy Performance Certificate

Annexe, 1 Drummond Road, Goring-by-Sea, BN12 4DX

EPC Report

Energy rating

Current: 67 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 68 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 91 Potential: 91
Field Value
LMK KEY 0076-2810-7587-2520-3801
ADDRESS1 Annexe
ADDRESS2 1 Drummond Road
ADDRESS3 Goring-by-Sea
POSTCODE BN12 4DX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2020-08-20
LOCAL AUTHORITY E07000229
CONSTITUENCY E14001599
COUNTY
LODGEMENT DATE 2020-08-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 351
ENERGY CONSUMPTION POTENTIAL 30
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 37
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 252
HEATING COST POTENTIAL 237
HOT WATER COST CURRENT 87
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 25
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Annexe, 1 Drummond Road, Goring-by-Sea
LOCAL AUTHORITY LABEL Worthing
CONSTITUENCY LABEL Worthing West
POSTTOWN WORTHING
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-08-20 12:21:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100061886103
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew