Energy Performance Certificate
Arlecdon Parks Farm, Arlecdon Parks Road, Arlecdon, CA26 3XG
Energy rating
Current: 77 C | Potential: 90 B
Environmental impact (CO₂)
Current: 68
| Potential: 83
| Field | Value |
|---|---|
| LMK KEY | 0073-2883-6243-9705-4655 |
| ADDRESS1 | Arlecdon Parks Farm |
| ADDRESS2 | Arlecdon Parks Road |
| ADDRESS3 | Arlecdon |
| POSTCODE | CA26 3XG |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY EFFICIENCY | 90 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2015-04-07 |
| LOCAL AUTHORITY | E06000063 |
| CONSTITUENCY | E14001583 |
| COUNTY | — |
| LODGEMENT DATE | 2015-04-07 |
| TRANSACTION TYPE | RHI application |
| ENVIRONMENT IMPACT CURRENT | 68 |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| ENERGY CONSUMPTION CURRENT | 159 |
| ENERGY CONSUMPTION POTENTIAL | 85 |
| CO2 EMISSIONS CURRENT | 9.3 |
| CO2 EMISS CURR PER FLOOR AREA | 28 |
| CO2 EMISSIONS POTENTIAL | 5.1 |
| LIGHTING COST CURRENT | 119 |
| LIGHTING COST POTENTIAL | 119 |
| HEATING COST CURRENT | 2107 |
| HEATING COST POTENTIAL | 1658 |
| HOT WATER COST CURRENT | 57 |
| HOT WATER COST POTENTIAL | 57 |
| TOTAL FLOOR AREA | 326 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 3 |
| NUMBER HABITABLE ROOMS | 8 |
| NUMBER HEATED ROOMS | 8 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system, plus solar |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, insulated |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated at rafters |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.81 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | Y |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Arlecdon Parks Farm, Arlecdon Parks Road, Arlecdon |
| LOCAL AUTHORITY LABEL | Cumberland |
| CONSTITUENCY LABEL | Whitehaven and Workington |
| POSTTOWN | FRIZINGTON |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2015-04-07 13:24:07 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 28 |
| LOW ENERGY FIXED LIGHT COUNT | 28 |
| UPRN | 10000891403 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |