Energy Performance Certificate

36, Stentaway Road, PL9 7EH

EPC Report

Energy rating

Current: 77 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 77 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 82 Potential: 82
Field Value
LMK KEY 0068-4076-6216-9582-8914
ADDRESS1 36, Stentaway Road
ADDRESS2
ADDRESS3
POSTCODE PL9 7EH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-06-06
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001495
COUNTY
LODGEMENT DATE 2012-06-06
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 97
ENERGY CONSUMPTION POTENTIAL 68
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 644
HEATING COST POTENTIAL 651
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 93
TOTAL FLOOR AREA 211
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36, Stentaway Road
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL South West Devon
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2012-06-06 10:35:05
TENURE
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100040491372
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew