Energy Performance Certificate

Apartment 14 Victoria House, Scholars Court, ST4 7DW

EPC Report

Energy rating

Current: 80 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 82 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 82 Potential: 82
Field Value
LMK KEY 0065-2844-6830-9101-6871
ADDRESS1 Apartment 14 Victoria House
ADDRESS2 Scholars Court
ADDRESS3
POSTCODE ST4 7DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2019-07-04
LOCAL AUTHORITY E06000021
CONSTITUENCY E14001520
COUNTY
LODGEMENT DATE 2019-07-04
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 122
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 212
HEATING COST POTENTIAL 212
HOT WATER COST CURRENT 127
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 69
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1.27
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Apartment 14 Victoria House, Scholars Court
LOCAL AUTHORITY LABEL Stoke-on-Trent
CONSTITUENCY LABEL Stoke-on-Trent Central
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2019-07-04 07:39:32
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 3455126017
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000005
Address display
Nation ew