Energy Performance Certificate

1 Cherry Green Close, RH1 6RY

EPC Report

Energy rating

Current: 41 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 76 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 88 Potential: 88
Field Value
LMK KEY 0064-3059-8209-5636-2200
ADDRESS1 1 Cherry Green Close
ADDRESS2
ADDRESS3
POSTCODE RH1 6RY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2026-01-06
LOCAL AUTHORITY E07000211
CONSTITUENCY E14001442
COUNTY
LODGEMENT DATE 2026-02-18
TRANSACTION TYPE Grant scheme
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL 167
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 2119
HEATING COST POTENTIAL 1187
HOT WATER COST CURRENT 599
HOT WATER COST POTENTIAL 301
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Cherry Green Close
LOCAL AUTHORITY LABEL Reigate and Banstead
CONSTITUENCY LABEL Reigate
POSTTOWN REDHILL
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2026-02-18 18:58:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 68146336
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew