Energy Performance Certificate

3 Hall Terrace, SA17 5SN

EPC Report

Energy rating

Current: 70 C | Potential: 116 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 116 A Potential: 116 A

Environmental impact (CO₂)

Current: 47 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 97 Potential: 97
Field Value
LMK KEY 0054-0200-9702-4381-4810
ADDRESS1 3 Hall Terrace
ADDRESS2
ADDRESS3
POSTCODE SA17 5SN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 116
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-05-07
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000098
COUNTY
LODGEMENT DATE 2022-05-25
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 385
ENERGY CONSUMPTION POTENTIAL 22
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 565
HEATING COST POTENTIAL 377
HOT WATER COST CURRENT 282
HOT WATER COST POTENTIAL 144
TOTAL FLOOR AREA 77
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Hall Terrace
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Llanelli
POSTTOWN FERRYSIDE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-05-25 22:24:08
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10004849481
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew