Energy Performance Certificate

Flat 9, Arundel House, 22 The Drive, BN3 3JD

EPC Report

Energy rating

Current: 50 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 28 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 56 Potential: 56
Field Value
LMK KEY 0050-2368-2212-2302-2031
ADDRESS1 Flat 9
ADDRESS2 Arundel House
ADDRESS3 22 The Drive
POSTCODE BN3 3JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2022-09-08
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001296
COUNTY
LODGEMENT DATE 2022-09-08
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 482
ENERGY CONSUMPTION POTENTIAL 241
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 82
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 1743
HEATING COST POTENTIAL 715
HOT WATER COST CURRENT 263
HOT WATER COST POTENTIAL 263
TOTAL FLOOR AREA 124
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 0
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1.12
FLOOR HEIGHT 2.84
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 9, Arundel House, 22 The Drive
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Hove and Portslade
POSTTOWN HOVE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-09-08 15:30:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 22036523
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew