Energy Performance Certificate

21, Burnt Oak, Cookham, SL6 9RL

EPC Report

Energy rating

Current: 52 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 44 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 58 Potential: 58
Field Value
LMK KEY 0049-2858-7464-9206-6545
ADDRESS1 21, Burnt Oak
ADDRESS2 Cookham
ADDRESS3
POSTCODE SL6 9RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-06-08
LOCAL AUTHORITY E06000040
CONSTITUENCY E14001348
COUNTY
LODGEMENT DATE 2016-06-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 328
ENERGY CONSUMPTION POTENTIAL 221
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 108
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 1114
HEATING COST POTENTIAL 994
HOT WATER COST CURRENT 114
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 104
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Burnt Oak, Cookham
LOCAL AUTHORITY LABEL Windsor and Maidenhead
CONSTITUENCY LABEL Maidenhead
POSTTOWN MAIDENHEAD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-06-13 18:54:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100080352298
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew