Energy Performance Certificate

Flat 1, 50 Heneage Road, DN32 9ES

EPC Report

Energy rating

Current: 58 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 61 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 72 Potential: 72
Field Value
LMK KEY 0045-2858-7859-9026-3291
ADDRESS1 Flat 1
ADDRESS2 50 Heneage Road
ADDRESS3
POSTCODE DN32 9ES
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2016-05-28
LOCAL AUTHORITY E06000012
CONSTITUENCY E14001255
COUNTY
LODGEMENT DATE 2016-05-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 397
ENERGY CONSUMPTION POTENTIAL 293
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 18
LIGHTING COST POTENTIAL 18
HEATING COST CURRENT 344
HEATING COST POTENTIAL 253
HOT WATER COST CURRENT 64
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 19
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, 50 Heneage Road
LOCAL AUTHORITY LABEL North East Lincolnshire
CONSTITUENCY LABEL Great Grimsby and Cleethorpes
POSTTOWN GRIMSBY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-05-28 20:06:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 2
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 11071551
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew