Energy Performance Certificate

306 King Henry Terrace, Sovereign Court, Wapping, E1W 3HW

EPC Report

Energy rating

Current: 69 C | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 64 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 65 Potential: 65
Field Value
LMK KEY 0043-0294-9575-3989-6380
ADDRESS1 306 King Henry Terrace, Sovereign Court, Wapping
ADDRESS2
ADDRESS3
POSTCODE E1W 3HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-04-01
LOCAL AUTHORITY E09000030
CONSTITUENCY E14001430
COUNTY
LODGEMENT DATE 2025-04-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 280
ENERGY CONSUMPTION POTENTIAL 271
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 794
HEATING COST POTENTIAL 756
HOT WATER COST CURRENT 291
HOT WATER COST POTENTIAL 291
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 306 King Henry Terrace, Sovereign Court, Wapping
LOCAL AUTHORITY LABEL Tower Hamlets
CONSTITUENCY LABEL Poplar and Limehouse
POSTTOWN London
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2025-04-01 14:46:50
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 23
UPRN 6117515
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew