Energy Performance Certificate

123, Second Avenue, Carlton, NG4 1PF

EPC Report

Energy rating

Current: 60 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 54 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 84 Potential: 84
Field Value
LMK KEY 0038-2887-7783-9005-7685
ADDRESS1 123, Second Avenue
ADDRESS2 Carlton
ADDRESS3
POSTCODE NG4 1PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-08-03
LOCAL AUTHORITY E07000173
CONSTITUENCY E14001245
COUNTY
LODGEMENT DATE 2015-08-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 284
ENERGY CONSUMPTION POTENTIAL 85
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 735
HEATING COST POTENTIAL 427
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 80
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.503
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 123, Second Avenue, Carlton
LOCAL AUTHORITY LABEL Gedling
CONSTITUENCY LABEL Gedling
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-08-11 10:41:15
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100031379672
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew