Energy Performance Certificate

11b, Danefield Terrace, L19 4TH

EPC Report

Energy rating

Current: 48 E | Potential: 63 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 63 D Potential: 63 D

Environmental impact (CO₂)

Current: 42 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 58 Potential: 58
Field Value
LMK KEY 0037-2871-7436-9405-3515
ADDRESS1 11b, Danefield Terrace
ADDRESS2
ADDRESS3
POSTCODE L19 4TH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 63
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-07-09
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001337
COUNTY
LODGEMENT DATE 2015-07-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 369
ENERGY CONSUMPTION POTENTIAL 249
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1095
HEATING COST POTENTIAL 797
HOT WATER COST CURRENT 119
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.62
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS 11b, Danefield Terrace
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Garston
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-07-09 15:23:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 38198868
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew