Energy Performance Certificate

17 Hillside, Briston, NR24 2DW

EPC Report

Energy rating

Current: 51 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 50 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 70 Potential: 70
Field Value
LMK KEY 0035-7328-6500-0025-3202
ADDRESS1 17 Hillside
ADDRESS2 Briston
ADDRESS3
POSTCODE NR24 2DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2025-08-05
LOCAL AUTHORITY E07000147
CONSTITUENCY E14001396
COUNTY
LODGEMENT DATE 2025-08-05
TRANSACTION TYPE Grant scheme
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 273
ENERGY CONSUMPTION POTENTIAL 157
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 1100
HEATING COST POTENTIAL 766
HOT WATER COST CURRENT 364
HOT WATER COST POTENTIAL 305
TOTAL FLOOR AREA 68
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 17 Hillside, Briston
LOCAL AUTHORITY LABEL North Norfolk
CONSTITUENCY LABEL North Norfolk
POSTTOWN MELTON CONSTABLE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2025-08-05 12:26:16
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 10034790412
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew