Energy Performance Certificate

27 Trewern, Saron, SA44 5DS

EPC Report

Energy rating

Current: 60 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 53 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 75 Potential: 75
Field Value
LMK KEY 0032-9327-7100-0110-4292
ADDRESS1 27 Trewern
ADDRESS2 Saron
ADDRESS3
POSTCODE SA44 5DS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Bungalow
BUILT FORM End-Terrace
INSPECTION DATE 2022-03-10
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000087
COUNTY
LODGEMENT DATE 2022-03-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 268
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 444
HEATING COST POTENTIAL 353
HOT WATER COST CURRENT 161
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27 Trewern, Saron
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Caerfyrddin
POSTTOWN LLANDYSUL
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2022-03-10 19:32:10
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10004849693
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew