Energy Performance Certificate

6, Leeson Close, Colwick, NG4 2AT

EPC Report

Energy rating

Current: 81 B | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 84 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 84 Potential: 84
Field Value
LMK KEY 0031-3003-2304-5562-7204
ADDRESS1 6
ADDRESS2 Leeson Close
ADDRESS3 Colwick
POSTCODE NG4 2AT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 81
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-04-07
LOCAL AUTHORITY E07000173
CONSTITUENCY E14001245
COUNTY
LODGEMENT DATE 2022-04-07
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 115
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 202
HEATING COST POTENTIAL 202
HOT WATER COST CURRENT 58
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 54
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.23 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.08 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 6, Leeson Close, Colwick
LOCAL AUTHORITY LABEL Gedling
CONSTITUENCY LABEL Gedling
POSTTOWN Nottingham
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2022-04-07 08:41:28
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10035285994
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew