Energy Performance Certificate

R816, Kings Park, Creek Road, SS8 8QT

EPC Report

Energy rating

Current: 55 D | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 35 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 45 Potential: 45
Field Value
LMK KEY 0031-2190-5010-2499-9021
ADDRESS1 R816
ADDRESS2 Kings Park
ADDRESS3 Creek Road
POSTCODE SS8 8QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE Park home
BUILT FORM Detached
INSPECTION DATE 2021-09-10
LOCAL AUTHORITY E07000069
CONSTITUENCY E14001154
COUNTY
LODGEMENT DATE 2021-09-10
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 467
ENERGY CONSUMPTION POTENTIAL 369
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 859
HEATING COST POTENTIAL 628
HOT WATER COST CURRENT 225
HOT WATER COST POTENTIAL 196
TOTAL FLOOR AREA 70
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Park home wall, with external insulation
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.282
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS R816, Kings Park, Creek Road
LOCAL AUTHORITY LABEL Castle Point
CONSTITUENCY LABEL Castle Point
POSTTOWN CANVEY ISLAND
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2021-09-10 09:46:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10004935153
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew