Energy Performance Certificate

2, Lindrick Drive, DN21 1FY

EPC Report

Energy rating

Current: 79 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 77 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 85 Potential: 85
Field Value
LMK KEY 0025-3877-7617-9404-2215
ADDRESS1 2, Lindrick Drive
ADDRESS2
ADDRESS3
POSTCODE DN21 1FY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-09-03
LOCAL AUTHORITY E07000142
CONSTITUENCY E14001243
COUNTY
LODGEMENT DATE 2014-09-03
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 123
ENERGY CONSUMPTION POTENTIAL 77
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 598
HEATING COST POTENTIAL 607
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 63
TOTAL FLOOR AREA 169
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 41
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.22 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.35 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.29 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 41% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2, Lindrick Drive
LOCAL AUTHORITY LABEL West Lindsey
CONSTITUENCY LABEL Gainsborough
POSTTOWN GAINSBOROUGH
CONSTRUCTION AGE BAND 2013
LODGEMENT DATETIME 2014-09-03 10:55:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10013813496
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew