Energy Performance Certificate

Flat 2, 78 Horninglow Road, DE14 2PT

EPC Report

Energy rating

Current: 39 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 46 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 60 Potential: 60
Field Value
LMK KEY 0020-2489-7079-2872-6975
ADDRESS1 Flat 2
ADDRESS2 78 Horninglow Road
ADDRESS3
POSTCODE DE14 2PT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-03-31
LOCAL AUTHORITY E07000193
CONSTITUENCY E14001143
COUNTY
LODGEMENT DATE 2022-04-01
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 543
ENERGY CONSUMPTION POTENTIAL 393
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 92
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 38
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 1030
HEATING COST POTENTIAL 371
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 196
TOTAL FLOOR AREA 36
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.966
FLOOR HEIGHT 2.77
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2, 78 Horninglow Road
LOCAL AUTHORITY LABEL East Staffordshire
CONSTITUENCY LABEL Burton and Uttoxeter
POSTTOWN BURTON-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-04-01 12:47:24
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 3
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10090988274
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew