Energy Performance Certificate

Flat 1, 114 Clarendon Road, LA3 1SD

EPC Report

Energy rating

Current: 61 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 55 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 71 Potential: 71
Field Value
LMK KEY 0018-2848-7799-9525-2895
ADDRESS1 Flat 1
ADDRESS2 114 Clarendon Road
ADDRESS3
POSTCODE LA3 1SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-01-28
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001372
COUNTY
LODGEMENT DATE 2015-01-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 280
ENERGY CONSUMPTION POTENTIAL 179
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 759
HEATING COST POTENTIAL 500
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, 114 Clarendon Road
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Morecambe and Lunesdale
POSTTOWN MORECAMBE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-01-28 08:15:07
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10009283633
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew