Energy Performance Certificate
12, Elvet Close, Wideopen, NE13 7HE
Energy rating
Current: 56 D | Potential: 81 B
Environmental impact (CO₂)
Current: 50
| Potential: 79
| Field | Value |
|---|---|
| LMK KEY | 0012-2814-7830-9727-9575 |
| ADDRESS1 | 12, Elvet Close |
| ADDRESS2 | Wideopen |
| ADDRESS3 | — |
| POSTCODE | NE13 7HE |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 56 |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2013-07-24 |
| LOCAL AUTHORITY | E08000022 |
| CONSTITUENCY | E14001183 |
| COUNTY | — |
| LODGEMENT DATE | 2013-07-24 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 50 |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| ENERGY CONSUMPTION CURRENT | 288 |
| ENERGY CONSUMPTION POTENTIAL | 127 |
| CO2 EMISSIONS CURRENT | 6.3 |
| CO2 EMISS CURR PER FLOOR AREA | 55 |
| CO2 EMISSIONS POTENTIAL | 2.8 |
| LIGHTING COST CURRENT | 110 |
| LIGHTING COST POTENTIAL | 60 |
| HEATING COST CURRENT | 990 |
| HEATING COST POTENTIAL | 679 |
| HOT WATER COST CURRENT | 213 |
| HOT WATER COST POTENTIAL | 79 |
| TOTAL FLOOR AREA | 113 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer and room thermostat |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | 2 |
| NUMBER HABITABLE ROOMS | 6 |
| NUMBER HEATED ROOMS | 6 |
| LOW ENERGY LIGHTING | 16 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, limited insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 16% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.267 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 12, Elvet Close, Wideopen |
| LOCAL AUTHORITY LABEL | North Tyneside |
| CONSTITUENCY LABEL | Cramlington and Killingworth |
| POSTTOWN | NEWCASTLE UPON TYNE |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2013-07-24 20:06:33 |
| TENURE | Owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 19 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| UPRN | 47032856 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2013.csv |
| COUNTRY | England |
| REGION | E12000001 |
| Address display | — |
| Nation | ew |