Energy Performance Certificate

2 LONGSTONE COTTAGES, LONGSTONE HILL, CARBIS BAY, TR26 2LJ

EPC Report

Energy rating

Current: 24 F | Potential: 124 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 124 A Potential: 124 A

Environmental impact (CO₂)

Current: 35 | Potential: 123
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 123 Potential: 123
Field Value
LMK KEY 0011-2131-3070-2309-3295
ADDRESS1 2 LONGSTONE COTTAGES
ADDRESS2 LONGSTONE HILL
ADDRESS3 CARBIS BAY
POSTCODE TR26 2LJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 124
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-03-09
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2021-03-29
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 123
ENERGY CONSUMPTION CURRENT 585
ENERGY CONSUMPTION POTENTIAL -246
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL -1.8
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 941
HEATING COST POTENTIAL 224
HOT WATER COST CURRENT 577
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 44
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 LONGSTONE COTTAGES, LONGSTONE HILL, CARBIS BAY
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN CARBIS BAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-03-29 13:34:32
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10023313196
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew