Energy Performance Certificate

57 PARK STREET, B79 7QP

EPC Report

Energy rating

Current: 20 G | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 5 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 5 Current: 5 72 Potential: 72
Field Value
LMK KEY 0010-2901-9360-2409-9971
ADDRESS1 57 PARK STREET
ADDRESS2
ADDRESS3
POSTCODE B79 7QP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-06-09
LOCAL AUTHORITY E07000199
CONSTITUENCY E14001538
COUNTY
LODGEMENT DATE 2021-06-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 5
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 1026
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 175
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 2151
HEATING COST POTENTIAL 611
HOT WATER COST CURRENT 316
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 76
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 60
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.598
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 57 PARK STREET
LOCAL AUTHORITY LABEL Tamworth
CONSTITUENCY LABEL Tamworth
POSTTOWN TAMWORTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-06-22 13:21:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 394019959
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew