Energy Performance Certificate

4, Ambleside, Station Road, AL5 4RR

EPC Report

Energy rating

Current: 65 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 65 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 87 Potential: 87
Field Value
LMK KEY 0010-2883-7996-9294-2375
ADDRESS1 4, Ambleside
ADDRESS2 Station Road
ADDRESS3
POSTCODE AL5 4RR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-01-17
LOCAL AUTHORITY E07000240
CONSTITUENCY E14001268
COUNTY
LODGEMENT DATE 2014-01-19
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 226
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 461
HEATING COST POTENTIAL 394
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 59
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Ambleside, Station Road
LOCAL AUTHORITY LABEL St Albans
CONSTITUENCY LABEL Harpenden and Berkhamsted
POSTTOWN HARPENDEN
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-01-19 19:17:38
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100081131355
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew